The cheapest time to get heating and cooling right is before the walls close. We size equipment from a load calculation, lay out ducts that fit the framing, and work to your build schedule from rough-in to final.

Answering 24/7 from our Monticello Ave office in New Orleans

  • Answering 24/7
  • Builders and owner-builders
  • Raised and slab houses

Updated October 2026

Short answer

New construction HVAC starts with a room-by-room load calculation, then equipment chosen to match it, then a duct layout drawn around the framing. Ducts, line sets and drains are roughed in before insulation and drywall; equipment is set and started after finishes. In a humid climate the load matters most, because an oversized system cools fast and leaves rooms damp.

Getting it right before the walls close

Supply ducts being roughed in between new framing in a raised New Orleans house

Most comfort problems in newer houses were built in: equipment picked by square footage, ducts squeezed into whatever space was left, returns too small to feed the blower. We start from a load calculation that accounts for windows, insulation, orientation and how the rooms are used, then pick equipment and design ducts to that number.

Coordination is the other half. Ducts and line sets need chases the framer leaves open, the electrician needs the circuit sizes early, and the plumber needs to know where condensate drains will run. We set those details with your builder at the start so nobody cuts a joist to make room later. We install Carrier, Trane, Lennox and other major lines.

What drives the cost of a new-build system

New construction is priced from the plans, so there is no honest single figure to publish. These are the factors that move it.

  • House size and load. The load calculation sets equipment size, the biggest single cost.
  • System type. Single-stage, two-stage and variable-speed systems differ widely in price.
  • Duct layout. Under-floor runs, attic runs and long trunk lines change material and labor.
  • Zoning and controls. Two-story homes often need zoning or a second system.
  • Humidity and fresh air. Dehumidifiers and ventilation add equipment but prevent clammy rooms.

What our new-construction scope covers

  • Room-by-room load calculation
  • Equipment selection and submittals
  • Supply and return duct design
  • Rough-in of ducts, line sets and drains
  • Thermostat and control wiring
  • Equipment set, charge and start-up
  • Start-up readings for the builder and owner

Load calculations and picking the equipment

A load calculation estimates how much heat each room gains in summer and loses in winter, using the actual windows, wall and attic insulation, orientation and air tightness. From it we choose equipment that covers the load without large oversizing, and we look hard at moisture removal, since a tight new house in this climate can stay clammy if the system cycles off too quickly. That often points to a variable-speed system, a separate dehumidifier or fresh-air ventilation planned in from day one rather than added after complaints.

Rough-in, trim-out and inspections

Rough-in happens after framing and before insulation: supply and return ducts, refrigerant line sets, condensate drains, thermostat wire and any fresh-air ducts go in while everything is open. After drywall and paint we come back to set equipment, install grilles and thermostats, charge the system and start it. We keep the work ready for the inspector at each stage and walk the builder through the start-up readings, so the final inspection is a formality rather than a list of corrections.

Duct design for raised new builds

A house built on piers gives a choice most slab homes do not have: ducts under the floor or in the attic. Under-floor ducts stay out of the hottest space but sit in humid air and need sealing and insulation done properly to avoid sweating. Attic ducts are easier to service but fight attic heat all summer. On raised builds we also plan where the outdoor unit sits, usually on a platform above flood height, with line sets that do not have to climb awkwardly to reach it.

New builds on old ground in New Orleans

Builders here work with two very different kinds of house. Older homes sit on piers about three feet high, while much of New Orleans East went up as 20th-century slab homes with every duct in the attic. A new raised build can put ducts under the floor or overhead, and that choice reshapes the whole duct design. Any new central AC installed in Louisiana must meet at least 14.3 SEER2, so we treat that as a floor to size up from, never a target.

How we work with your build

  1. Plan reviewWe read the plans and talk through how the rooms will be used.
  2. Load calc and layoutWe run the load, choose equipment and draw the duct routes.
  3. Rough-inDucts, line sets, drains and wiring go in before insulation.
  4. Set and startAfter finishes we set equipment, charge it and start it up.
  5. Final and handoverWe support the final inspection and show the owner how it runs.

When each stage happens on the schedule

Our work comes in two visits that bracket the drywall. Rough-in follows framing and the other trades' rough work, and trim-out follows paint. The calendar time between them belongs to the build, so we schedule around the builder and keep a slot open for the rough-in inspection rather than asking the job to wait on us.

New systems we install in New Orleans builds, including Carrier, Trane, Lennox, Rheem and Daikin.

Brands we service and install: Carrier, Trane, Lennox, Rheem, Goodman, American Standard, Daikin, Mitsubishi Electric, Fujitsu, Bryant, Ruud, York, Amana, Honeywell.

Common questions

New construction HVAC questions

Related ac and heat pump installs work

AC Replacement

A matched outdoor and indoor system sized to the house, not the old label.

Central Air Installation

Central air for homes that have only ever had window units.

Air Handler Replacement

Attic and closet air handlers replaced, with new pans and drains.

Heat Pump Installation

Heat pumps that cool hard in August and heat through a January freeze.

Plans on the table? Call before the framing goes up

Tell us about the build and where it stands. We will tell you what we need from the plans and when we should be on site.

Answering 24/7(504) 520-4201Tap to call

Call or find us

One number, answered around the clock

Phone
(504) 520-4201
Hours
Open 24 hours, 7 days a week
Service office
3560 Monticello Ave, New Orleans, LA 70118
Head office
12784 Faircrest Dr, Washington, MI 48094
Coverage
New Orleans and the surrounding parishes

Our service office on Monticello Ave, by the Jefferson Parish line.

Call (504) 520-4201